Skip to main content
Version: 5.0

Equipment

Overview​

The Equipment page lists panels that are available to you in PowerManage. Use this page to add panels, review panel identity and status, control application access, and start panel management actions.

Use the Equipment page to:

  • Review panel identity, ownership, model, group, connection, first connection, events, troubles, and state.
  • Open Equipment hub for a selected panel.
  • Add a panel and record owner information and remarks.
  • Start configuration, discovery, diagnostic, service, fault, report, and remote inspection actions.
  • Enable or disable installer and customer application access.
  • Remove a panel from PowerManage.
Equipment page (light) Equipment page (dark)
note

Available data, actions, and menu items depend on panel type, panel state, server license, group assignment, and your role permissions.

Before you begin​

Required permissions​

Required permissions depend on the action that you want to complete.

  • You must have permission to view the Equipment page and listed panels.
  • You must have permission to add, edit, or remove panels to use the related actions.
  • You must have permission to run configuration, discovery, diagnostic, service, fault, report, and remote inspection actions.
  • You must have permission to control installer and customer application access.
info

Access to equipment and panel management actions is controlled by permissions in the Equipment permission group.

Preconditions​

  • Required panel identity, account, SIM, and group information must be available before you add a panel.
  • A panel must be selected before you run selection-based actions.
  • The panel must be reachable for actions that communicate with the panel.

Dependencies​

  • Panel types in the Type dropdown depend on the server license.
  • Connection, state, event, trouble, and first connection data depend on information received from the panel.
  • Available menu actions depend on panel state, existing faults, service assignment, and role permissions.
  • Basic configurations depend on entries that are compatible with the selected panel.
  • Report and remote inspection actions depend on the related PowerManage features and permissions.

Important limitations​

warning
  • Removing a panel removes it from the PowerManage server. Review the selected panel before you confirm removal.
  • Configuration, discovery, diagnostic, and state actions can fail when the panel is offline or does not connect before the selected timeout.
  • A menu item can be hidden when the action is not supported or your role does not include the required permission.

Page layout​

The page header shows the equipment count and page-level actions.

Equipment page header (light) Equipment page header (dark)
  1. Add panel button iconAdd panel buttonOpens the Add panel modal window. Use to add a panel to PowerManage.
  2. More actions button iconMore actions buttonOpens the More actions menu. Use to run an available action for selected equipment.

Add panel modal window​

The Add panel modal window organizes panel details into three tabs. Complete the fields that apply to the panel, and then select Save.

Add panel modal window, Panel information tab (light)Add panel modal window, Panel information tab (dark)
  1. Current stepShows the current step of the add-panel process. Use to track progress through the modal window.
  2. Type dropdownShows panel types available under the server license. Use to select the panel type.
  3. ID fieldAccepts the panel ID. Use to enter the unique panel identifier.
  4. Account fieldAccepts the panel account code. Use to enter the account code associated with the panel.
  5. SIM number fieldAccepts the panel SIM number. Use when the panel uses a SIM and the value is required.
  6. Group dropdownShows groups available for panel assignment. Use to assign the panel to a group.
note

The panel types shown in the Type dropdown depend on the server license.

Equipment grid​

Equipment grid (light) Equipment grid (dark)

The Equipment grid shows panel information, current status, and available controls.

  1. Checkbox iconCheckboxSelects a panel in the grid. Use to select equipment before running an applicable action.
  2. EquipmentShows the panel ID and account code. Use to identify the panel.
  3. OwnerShows the owner name and email address when owner information is set. Use to identify or contact the panel owner.
  4. Model / GroupShows the panel model and assigned group. Use to review panel type and group assignment.
  5. Blue BBA connection iconBlue BBA connection iconRed BBA connection iconRed BBA connection iconGray BBA connection iconGray BBA connection iconGray GPRS connection iconGray GPRS connection iconRed GPRS connection iconRed GPRS connection iconGreen GPRS connection iconGreen GPRS connection iconConnectionShows BBA and GPRS connection status icons. Blue indicates connected, gray indicates installed, red indicates offline, and green indicates online. Use to review panel connectivity and available communication channels.
  6. First connection iconFirst connectionShows the panel first connection date and time. Use to review when the panel first connected to PowerManage.
  7. Red unhandled events bell iconEvents & Troubles iconEvents & Troubles iconEvents & TroublesShows a red bell icon when the panel has unhandled events. Shows a trouble icon when the panel has active trouble. When neither condition exists, a neutral indicator is shown. Use to identify panels that need attention.
  8. States iconStates iconStates iconStates iconStatesShows panel states by state type and partition. Use to review the current state of panel partitions.
  9. App toggles iconApp togglesEnables or disables Installer app and Customer app access for the panel. Use to control access through AlarmInstall and ConnectAlarm.
  10. More menu iconMore menuOpens the More actions menu for the panel. Use to run panel-specific actions.
  11. State management and troubles widget arrow iconState management and troubles widget arrowOpens the State management and troubles widget. Use to review panel states, troubles, troubled devices, and bypass controls.

More actions menu​

The More actions menu groups panel actions by purpose. Available groups and actions depend on the selected panel, current panel state, and your permissions.

More actions menu, Create (light)More actions menu, Create (dark)
  1. Report iconReportOpens the Create new report modal window. Use to create a report for the selected panel. See the Reports page for details.

Push Basic Config modal window​

Push Basic Config modal window (light) Push Basic Config modal window (dark)
  1. Basic configurations dropdownShows only Basic configurations that are acceptable for the selected panel. Use to select a basic configuration.

Trigger discovery modal window​

Trigger discovery modal window (light) Trigger discovery modal window (dark)
  1. Timeout dropdownSets when discovery fails if the panel does not connect to the server. Values are Infinite, 10 minutes, 1 hour, 12 hours, 1 day, and 1 week. Use to define how long PowerManage waits for the panel.

Mark panel for service modal window​

Mark panel for service modal window (light) Mark panel for service modal window (dark)
  1. To dropdownShows the Task Pool and available employees. Use to assign the service task.
  2. Comment fieldAccepts a service comment. Use to record service details.

Reassign panel for service modal window​

Reassign panel for service modal window (light) Reassign panel for service modal window (dark)
  1. To dropdownShows the Task Pool and available employees. Use to select the new service assignment.
  2. Comment fieldAccepts a service comment. Use to record reassignment details.

Resolve faults modal window​

Resolve faults modal window (light) Resolve faults modal window (dark)
  1. Empty checkbox iconAll checkboxSelects all listed faults. Use to resolve every listed fault.
  2. Empty checkbox iconFaultShows a selection checkbox, fault name, and comment. Use to select individual faults.

Resume faults modal window​

Resume faults modal window (light) Resume faults modal window (dark)
  1. Empty checkbox iconAll checkboxSelects all listed faults. Use to resume every listed fault.
  2. Empty checkbox iconFaultShows a selection checkbox, fault name, and comment. Use to select individual suspended faults.

Suspend faults modal window​

Suspend faults modal window (light) Suspend faults modal window (dark)
  1. Empty checkbox iconAll checkboxSelects all listed faults. Use to suspend every listed fault.
  2. Empty checkbox iconFaultShows a selection checkbox, fault name, and comment. Use to select individual active faults.
  3. Date fieldSuspend a faults until a specified date. Use to suspend a faults until a specified date.

State management and troubles widget​

State management and troubles widget (light) State management and troubles widget (dark)

The State management and troubles widget shows panel states, active troubles, troubled devices, and supported controls.

  1. Low battery trouble iconMark for service trouble iconTroublesShows trouble count, panel time in fault state, and trouble details for the selected partition, including low battery and Mark for service indicators. When ALL is selected, troubles are shown for all partitions. Use to review current panel troubles.
  2. Eight colored partition state indicatorsStatesShows partitions, colored partition state icons, and an ALL button. Green means disarmed, red means armed away, yellow means armed home, and blue means armed night. Use to select a partition or all partitions.
  3. State control iconState control iconState control iconState control iconState controlShows state change buttons such as Away, Night, Stay, and Disarm for the selected partition. Use to apply a new state to a partition.
  4. Low battery iconTroubled devicesShows only troubled devices with device icon, zone type, zone number, zone name, and trouble icons. Use to review devices that require attention.
  5. Bypass toggle iconBypass toggleShows next to each bypassable troubled device. Use to bypass a troubled device when supported.
note
  • Suspended faults are shown greyed out. If a fault has a comment, the comment is shown near the fault.
  • The States area is not supported for Fibro transmitters or manually enrolled panels with unfinished first discovery.
  • The Bypass section shows only troubled devices. Devices without troubles and non-bypassable devices are not shown.
  • Additional arming parameters depend on the panel type.

App toggles​

App toggles (light) App toggles (dark)

The app toggles control access to the selected panel through the installer and customer applications.

  1. Installer app iconEnabled toggle iconInstaller app toggleAllows installers to sign in to the panel through the AlarmInstall app when enabled. When disabled, installers cannot sign in to the panel through AlarmInstall. Use to allow or prevent installer application access for the panel.
  2. Customer app iconDisabled toggle iconCustomer app toggleAllows customers to sign in to the panel through the ConnectAlarm app when enabled. When disabled, customers cannot sign in to the panel through ConnectAlarm. Use to allow or prevent customer application access for the panel.

Pagination controls​

Pagination controls appear at the bottom of the entries grid.

Pagination controls (light theme) pagination controls (dark)
  1. Previous and next arrows iconPrevious and next arrows iconPrevious and next arrowsMove between pages when the list contains more records than one page can show.
  2. Range indicatorShows the current range and total number of entries.
  3. Entries per page selectorControls how many entries appear on one page.

The Search bar lets you search for entries on the page, access saved filters, reopen recently visited entries and latest searches, and open the filter widget.

info

Last visited entries and latest searches are limited to five items. They are stored locally in the browser and managed as FIFO.

Search bar, light themeSearch Bar Dark
  1. Search iconSearchSearch icon used to initiate a search. Use when you want to find a specific entry or set of entries.
  2. Latest searches iconLatest searchesSearch field that displays up to five latest search queries. Latest searches appear after clicking the search field. Use when you want to enter a new search query or quickly repeat a recent search.
  3. Saved filters iconSaved filtersDisplays filter entries that have been saved for reuse. Use when you want to quickly apply a previously saved filter.
  4. Last visited iconLast visitedDisplays the five most recently visited entries. Use when you want to quickly reopen entries that were accessed recently.
  5. Show filters iconShow filtersOpens the filter widget and displays the available filtering options. Use when you need to add, modify, or remove filter criteria.
  6. Delete a last visited entry or latest search iconDelete a last visited entry or latest searchRemoves the corresponding search or last visited query from the list. Use when you want to remove a search query or last visited entry from the list.

Common scenarios​

Add a panel​

Goal:

  • Add a panel to PowerManage and record available owner information and remarks.

Steps:

  1. On the Equipment page, select Add panel.
  2. On the Panel information tab, select the panel type.
  3. Enter the panel ID, account code, and SIM number when required.
  4. Select a group.
  5. On the Owner information tab, enter the available owner details.
  6. On the Remarks tab, enter any relevant panel remarks.
  7. Select Save.

Expected result:

  • PowerManage adds the panel when all required values are valid.
  • The panel appears in the Equipment grid.

Open Equipment hub​

Goal:

  • Open detailed information and management tools for a panel.

Steps:

  1. Find the panel in the Equipment grid.
  2. Select the panel row.

Expected result:

  • Equipment hub opens for the selected panel.
  • Available tabs and actions depend on the panel type, discovery state, and your permissions.

Set a panel state​

Goal:

  • Arm, disarm, or change the state of a panel partition.

Steps:

  1. Locate the required panel in the Equipment grid.
  2. Select the State management and troubles widget arrow.
  3. Select the required partition.
  4. Select the desired state:
    • Away
    • Stay
    • Night
    • Disarm
  5. Confirm the action if prompted.

Expected result:

  • The selected partition changes to the requested state.
  • The state indicator updates in the Equipment grid.

Review active panel troubles​

Goal:

  • Identify active troubles affecting a panel.

Steps:

  1. Open the State management and troubles widget.
  2. Review the Troubles section.
  3. Select a trouble to view additional details and comments.

Expected result:

  • Active troubles are displayed with their current status and comments.

Bypass a troubled device​

Goal:

  • Temporarily bypass a device that prevents arming.

Steps:

  1. Open the State management and troubles widget.
  2. Select the required partition.
  3. Locate the device in the Troubled devices list.
  4. Enable the Bypass toggle.

Expected result:

  • The selected device is bypassed.
  • The panel can be armed according to panel capabilities.

Review panel status​

Goal:

  • Check panel connectivity, state, events, and troubles.

Steps:

  1. Find the panel in the Equipment grid.
  2. Review Connection.
  3. Review Events & Troubles.
  4. Review States.
  5. If more detail is needed, select the State management and troubles widget arrow.

Expected result:

  • The grid shows the current information received from the panel.
  • The widget shows available state, trouble, and troubled-device details.

Refresh panel state​

Goal:

  • Request the current state from a panel.

Steps:

  1. Open the panel More actions menu.
  2. Select Configuration.
  3. Select Refresh state.

Expected result:

  • PowerManage starts the Refresh state process for the panel.

Download panel configuration​

Goal:

  • Request the current configuration from a panel.

Steps:

  1. Open the panel More actions menu.
  2. Select Configuration.
  3. Select Refresh configuration.

Expected result:

  • PowerManage starts the Download configuration process for the panel.

Push a basic configuration​

Goal:

  • Upload a compatible basic configuration to a panel.

Steps:

  1. Open the panel More actions menu.
  2. Select Configuration.
  3. Select Push basic configuration.
  4. In Basic configurations, select a configuration.
  5. Select Push.

Expected result:

  • PowerManage starts the Upload configuration process with the selected basic configuration.

Trigger panel discovery​

Goal:

  • Start discovery for a panel.

Steps:

  1. Open the panel More actions menu.
  2. Select Management.
  3. Select Trigger discovery.
  4. Select a timeout.
  5. Select Save.

Expected result:

  • PowerManage starts the Discovery process.
  • The process fails after the selected timeout if the panel does not connect to the server.

Read diagnostic information​

Goal:

  • Request diagnostic information from a panel.

Steps:

  1. Open the panel More actions menu.
  2. Select Management.
  3. Select Read diagnostic.

Expected result:

  • PowerManage starts the Read diagnostic info process.

Mark a panel for service​

Goal:

  • Assign a panel to the Task Pool or an employee for service.

Steps:

  1. Open the panel More actions menu.
  2. Select Service assignment.
  3. Select Mark for service.
  4. In To, select the Task Pool or an employee.
  5. Enter a comment when needed.
  6. Select Save.

Expected result:

  • The panel is marked for service.
  • A related Mark for service trouble appears with the comment.

Reassign a panel for service​

Goal:

  • Change the service assignment for a panel.

Steps:

  1. Open the panel More actions menu.
  2. Select Service assignment.
  3. Select Reassign.
  4. Select the new Task Pool or employee assignment.
  5. Enter a comment when needed.
  6. Select Save.

Expected result:

  • PowerManage updates the service assignment and related comment.

Resolve panel faults​

Goal:

  • Resolve selected faults for a panel marked for service.

Steps:

  1. Open the panel More actions menu.
  2. Select Faults.
  3. Select Resolve.
  4. Select individual faults, or select All.
  5. Select Save.

Expected result:

  • Selected faults are resolved and no longer appear on the panel.

Suspend or resume panel faults​

Goal:

  • Change selected faults between active and suspended states.

Steps:

  1. Open the panel More actions menu.
  2. Select Faults.
  3. Select Suspend for active faults or Resume for suspended faults.
  4. Select individual faults, or select All.
  5. Select Save.

Expected result:

  • Suspended faults appear as suspended.
  • Resumed faults appear as active.

Control application access​

Goal:

  • Allow or prevent installer or customer application access to a panel.

Steps:

  1. Find the panel in the Equipment grid.
  2. Set the Installer app toggle to the required state.
  3. Set the Customer app toggle to the required state.

Expected result:

  • When enabled, the related application can access the panel.
  • When disabled, the related application cannot access the panel.

Remove a panel​

Goal:

  • Permanently remove a panel from PowerManage.

Steps:

  1. Confirm that the correct panel is selected.
  2. Open the panel More actions menu.
  3. Select Remove.
  4. Review the warning message.
  5. Select Yes, remove.

Expected result:

  • PowerManage permanently removes the panel from the Equipment grid.
warning

Removing a panel cannot be undone. Confirm the panel ID and account code before you remove the panel.

Field and option reference​

Panel connection status​

The communication channel icons show which channel is used by the panel.

  1. GPRS or cellular connection icon (light)GPRS or cellular connection icon (dark)GPRS or cellular connectionIndicates that the panel is communicating with the server via a cellular connection (GPRS).
  2. Wi-Fi connection icon (light)Wi-Fi connection icon (dark)Wi-Fi connectionIndicates that the panel is communicating with the server via a Wi-Fi connection.
  3. Ethernet or broadband connection icon (light)Ethernet or broadband connection icon (dark)Ethernet or broadband connectionIndicates that the panel is communicating with the server via an Ethernet (broadband) connection.
  4. Cellular connection through a dual-channel communicator board icon (light)Cellular connection through a dual-channel communicator board icon (dark)Cellular connection through an Ethernet boardIndicates that the panel is communicating with the server via a cellular connection through an Ethernet board.

The communication channel icon color shows the channel status.

  1. Gray BBA iconGray BBA iconInstalledIndicates that the communication module is physically installed in the panel, but no communication channel is present or configured or if the communication channel is configured, but keepalive messages are disabled in the panel's group settings, or the channel is configured but currently disconnected.
  2. Green BBA iconGreen BBA iconOnlineIndicates that the panel has an active communication channel and the server is receiving keepalive messages from the panel.
  3. Blue BBA iconBlue BBA iconConnectedIndicates that there is an open active connection (session) between the panel and the server.
  4. Red BBA iconRed BBA iconOfflineIndicates that the panel has a communication channel configured, but the server is no longer receiving keepalive messages from the panel.

Panel state colors​

  1. Disarmed iconDisarmedColor: Green. The partition is disarmed.
  2. Armed away iconArmed awayColor: Red. The partition is armed in Away mode.
  3. Armed home iconArmed homeColor: Yellow. The partition is armed in Home or Stay mode.
  4. Armed night iconArmed nightColor: Blue. The partition is armed in Night mode.

Application access toggles​

  1. Installer app iconInstaller appEnabled: Installers can sign in to the panel through AlarmInstall. Disabled: Installers cannot sign in to the panel through AlarmInstall.
  2. Customer app iconCustomer appEnabled: Customers can sign in to the panel through ConnectAlarm. Disabled: Customers cannot sign in to the panel through ConnectAlarm.

Tips​

tip
  • Confirm the panel ID and account code before you run a panel action.
  • Review Connection before you start an action that communicates with the panel.
  • Use the State management and troubles widget to review partition states and affected devices before changing panel state.
  • Add a service comment that explains the issue and expected action when you mark or reassign a panel for service.
  • Select a discovery timeout that gives the panel enough time to connect to the server.
  • Use Refresh state before acting on panel state information that might be outdated.
  • Review application access toggles when an installer or customer cannot access the panel through the related app.

Troubleshooting​

Add panel cannot be saved​

Possible causes:

  • A required field is empty or invalid.
  • The selected panel type is not available under the server license.
  • The panel ID, account code, SIM number, or group value is incorrect.
  • Your role does not allow adding panels.

What to try:

  1. Review all fields on the Panel information tab.
  2. Confirm that the selected panel type is covered by the server license.
  3. Confirm the panel ID, account code, SIM number, and group.
  4. Confirm that your role allows adding panels.
  5. Select Save again.

Expected action is not shown​

Possible causes:

  • The action is not supported for the selected panel.
  • The panel is not in the required state.
  • The required fault or service condition is not present.
  • Your role does not include the required permission.

What to try:

  1. Confirm that the correct panel is selected.
  2. Review panel state, faults, and service assignment.
  3. Confirm that the panel supports the action.
  4. Confirm your role permissions.

Panel action fails or times out​

Possible causes:

  • The panel is offline.
  • The panel did not connect before the process timeout.
  • Communication was interrupted.

What to try:

  1. Review the panel Connection status.
  2. Wait for the panel to reconnect.
  3. Start the action again.
  4. Review the related process for failure details.

Basic configuration is not listed​

Possible causes:

  • No compatible basic configuration exists.
  • The configuration is not acceptable for the selected panel.
  • Your role does not allow access to the configuration.

What to try:

  1. Confirm the selected panel type.
  2. Confirm that a compatible basic configuration exists.
  3. Confirm your permissions.
  4. Open Push Basic Config again.

State controls are not available​

Possible causes:

  • The panel type does not support the state controls.
  • The panel is a Fibro transmitter.
  • The panel was enrolled manually and first discovery is unfinished.
  • Your role does not allow state changes.

What to try:

  1. Confirm the panel type.
  2. Confirm that first discovery completed.
  3. Confirm your role permissions.
  4. Refresh the panel state.

Troubled device cannot be bypassed​

Possible causes:

  • The device is not bypassable.
  • The device does not have an active trouble.
  • Your role does not allow the action.

What to try:

  1. Confirm that the device appears in Troubled devices.
  2. Confirm that a Bypass toggle is shown for the device.
  3. Confirm your role permissions.

Installer or customer cannot access the panel​

Possible causes:

  • The related application toggle is disabled.
  • The panel is offline or unavailable.
  • The account or installer does not have access to the panel.

What to try:

  1. Review the Installer app or Customer app toggle.
  2. Enable the required toggle if access is allowed.
  3. Review panel connection status.
  4. Confirm the related account or installer assignment.
Was this page helpful?