< Previous | Contents | Next >
Connecting IQ panel through LwM2M protocol
To read and write IQ panel data through PowerManage and send IQ panel events to PowerManage, you must set up the LwM2M connection on the panel.
Related topics
Setting up LwM2M connection on the IQ panel UI
Setting up LwM2M connection on AlarmInstall
To set up the LwM2M connection on the IQ panel UI, complete the following steps.
1. Open the main menu, then tap SETTINGS > ADVANCED SETTINGS.
2. Enter the installer code or the dealer code.
3. Tap INSTALLATION > POWERMANAGE OPTIONS > PM SETTINGS.
4. Tick Primary and then tap the down arrow of the Dealer Id option.
5. Enter the dealer ID and then tap OK.
6. Go to back to the previous page and tap PM SERVER CONFIG.
7. Tap the pencil of primary receiver.
8. In the Host Name option, enter the PowerManage URL; in the Port Number option, enter 5685.
9. Tap SAVE.
You can set up the Fibro connection only through local connection of the AlarmInstall app with the IQ panel. For more information on how to connect AlarmInstall with the IQ panel, refer to the AlarmInstall instructions.
To set up the LwM2M connection through the AlarmInstall app, complete the following steps.
1. Connect AlarmInstall with the IQ panel.
2. On the lower side of Dashboard page, tap the Config icon.
3. Tap Installation > PowerManage Options.
4. Enable the Primary receiver and then tap on the right arrow.
5. In the Host Name option, enter the PowerManage URL; in the Port Number option, enter 5685.
6. Tap Save.
Related topics